FUJITSU E882 DRIVER DOWNLOAD

Indoor unit capacity error Indoor Unit Capacity Error — The total capacity of the indoor units has been exceeded or is under the minimum acceptable range. Refer to the Service Instruction manual — Serial. Connection unit number error Combination Unit Number Error — When the number of connecting indoor units are out of a specified rule. Heat Sink Thermistor Error — When heat-sink temperature thermistor is open or a short-circuit is detected at power up or while running the compressor. The power supply frequency cannot be recognized after 4 seconds of power on. Check for correct voltages at panel, condenser and evaporator.

Uploader: Voktilar
Date Added: 1 November 2007
File Size: 39.29 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 65359
Price: Free* [*Free Regsitration Required]

Pipe thermistor error Indoor Heat Ex. Current sensor error Current Sensor Error — When input current sensor has detected 0A, funitsu the inverter compressor is operating at higher than 56rps, after 1 minute upon starting the compressor.

AVerMedia USB MPEG-2 Capture Device (E882) Drivers

Compressor Thermistor Error — When the compressor temperature thermistor is open or short-circuit is detected at power up or while running the compressor. Combination Error — The outdoor unit received a signal that the applied indoor unit is that of a multi type.

Drain Pump Error — When the float switch is on for more than 3 minutes, error will trigger. Condenser fan motor error — Abnormal current or fan motor lock error was detected. When the compressor becomes hotter than Refer to the Service Instruction manual — Serial. High pressure switch error High Pressure Switch Error — When the pressure switch is detected open for longer than 10 seconds after the power is turned on.

  GIGAWARE PC CAMERA WITH MIC DRIVER

After the compressor restarts, if the same operation is repeated within. If voltage present replace wire remote control. Serial communication error Communication Error — At Start Up, evaporator and condenser are not communicating.

Check for running compressor with outdoor fan off. Discharge thermistor error Discharge Thermistor Error — When discharge pipe temperature thermistor open or short-circuit is detected at power on or while running the compressor. Intake grille error Intake Grille Error — When the micro switch is detected open while running the compressor.

Trip Detection — Protection stop by overcurrent generation after inverter compressor start processing completed generated consecutively 10 times. Connected combination error Connected Combination Error — When power is on and one of the below occurs:.

Check for erroneous connection or removed connector. If error code reappears check wiring from panel to condenser, condenser to evaporator. Outdoor unit inverter PCB error Rewriting shall be done upon erasing all the contents. Number of wires and pipes error Number of Wires and Pipes Error — When the operation command is inputted by the remote controller without check operation completion.

Damper Error — When limit switch was not able to detect the closing though the damper is closed.

Drivers for AVerMedia USB MPEG-2 Capture Device (E)

Evaporator fan motor error — The indoor fan speed is 0 RPM after 56 seconds from starting operation. Compressor thermistor error Compressor Thermistor Error — Compressor temperature thermistor is open or short-circuited while power is on or running the compressor.

  EPSON TM-U22OPD DRIVER DOWNLOAD

Suction gas thermistor error Suction Gas Thermistor Error — Suction gas temperature thermistor has shorted or open detected. Wired Remote Controller Communication Error — When the indoor unit cannot receive the signal from the Wired Remote Control for more than 1 minute during normal operation. Upper air flow -Check operation of limit switch. Over current error Trip Detection — Protection stop by overcurrent generation after inverter compressor start processing completed generated consecutively 10 times.

If fyjitsu pressure switch is open for 10 seconds when the power is turned on. Branch Box Error — When the branch box stops communicating with connected indoor units. Combination Unit Number Error — When the number of connecting indoor units are out of a specified rule. Check if there is any equipment that causes harmonic wave near the power cables, i. AC error codes w882 fujitsu halcyon inverter troubleshooting. Communication Error — At Start Up, evaporator and condenser are not communicating.

Check for correct voltage at. Indoor unit capacity error Indoor Unit Capacity Error — The total capacity of the indoor units has been exceeded or is under the minimum acceptable range.